CamSpec M108 Spectrophotometer

Camspec M508 Spectrophotometer 1
CamSpec M108

Single beam Visible M108 spectrophotometer with 2nm bandpass.

Easy to operate, intuitive instrument.

Wipe-clean LCD liquid crystal display and membrane keypad, ideal for laboratories that are hard to keep clean. 

Built in large memory to store up to 200 test modes.

Large range of accessories for laboratory automation and specific tests.

Complies with UKCA and CE requirements for safety and ESD/EMC emission and susceptibility.

Calibrated in the UK by qualified engineers using international standards for wavelength, absorbance, resolution and stray light.


Product Range Overview Video


Hear From Our Customers

Paul Douglas, Technical Assistant at Teesside University

“We’ve had great service. Mark and Paul are always easy to get hold of, and do the job excellently. They go above and beyond - in fact they’ve even tailored their software to a particular need we had in the past, which was extremely useful to us.”

Bev McGrath, Senior Technician at Liverpool John Moores University

“We work with you because you’ve always gone above and beyond to give us perfect service, and we’ve never been disappointed. I also like that you’re a family business.”

Operating Modes

  • Basic Mode (Abs, %T, Conc)
  • Quantitative (concentration calibration curves)
  • Wavelength Scanning (when connected to and controlled by PC)
  • Kinetics (including timedrive)
  • Multi-wavelength
  • Performance Validation

 

Software and PC Control

  • Local control with sealed, solvent resistant keypad
  • Remote control via PC CamSpec K3 Analyst application software
  • USB output for the transfer of results

 

Pharmacopoeias 

The CamSpec M108 passes the following pharmacopoeia tests:

  • Potassium Chloride stray light test
  • Toluene in Hexane resolution test
  • Holmium Perchlorate solution wavelength test
  • Potassium Dichromate absorbance test

Technical Specifications

DisplayTwo-line, 9-digits
Light SourceTungsten Halogen
MonochromatorSingle beam, grating system 1200 lines/nm
DetectorsSilicon Photodiode
Wavelenth Range325-1100nm
Wavelength Accuracy±2nm
Wavelength Repeatability≤1nm
Wavelength Display1nm
Stability±0.002A/hr@500nm
Sample CompartmentAccommodates 100mm path length cuvette with optional holder
Standard Cell Holder4 position 10mm cell changer
SoftwareK3 Analyst, optional
Zero Drift<0.003A per hour after warm up
Bandpass2nm
Stray Light<0.2%T@220nm and 360nm
Photometric Accuracy±0.5%T
Photometric Range0-125%T, -0.097-1.999A, 0-1999C (0-1999F)
Printer InterfaceBluetooth
Computer InterfaceUSB for PC control and USB for data export
Power Requirements90V-250V AC, 50Hz/60Hz
Instrument Dimensions (lxwxh)510x420x210
Instrument Weight 11.7kg
Shipping Dimensions (lxwxh)650x550x390mm
Shipping Weight13.5kg