CamSpec M550V Spectrophotometer

CamSpec M550 Spectrophotometer
CamSepc M550

Double beam UV-Vis M550V spectrophotometer designed for research and routine use.

Variable bandpass instrument with options for 0.5, 1, 2 and 4nm bandpasses.

Local or remote control via PC software and USB interface for transfer of results.

Complies with UKCA and CE requirements for safety and ESD/EMC emission and susceptibility.

Parallel sample and reference beams are included as part of the design.

Exceptional sensitivity, resolution, stray light, noise and drift specifications.

Large range of accessories for laboratory automation and specific tests.

Calibrated in the UK using international standards for wavelength, absorbance, resolution and stray light by our qualified engineers.


Product Range Overview Video


Hear From Our Customers

Paul Douglas, Technical Assistant at Teesside University

“We’ve had great service. Mark and Paul are always easy to get hold of, and do the job excellently. They go above and beyond - in fact they’ve even tailored their software to a particular need we had in the past, which was extremely useful to us.”

Bev McGrath, Senior Technician at Liverpool John Moores University

“We work with you because you’ve always gone above and beyond to give us perfect service, and we’ve never been disappointed. I also like that you’re a family business.”

Operating Modes

  • Basic Mode (Abs, %T, Conc)
  • Quantitative (concentration calibration curves)
  • Wavelength Scanning
  • Kinetics (including timedrive)
  • DNA/Protein
  • Multi-Wavelength
  • Performance Validation

 

Software and PC Control

  • Local control with wipe-clean membrane keypad
  • Remote control via PC CamSpec UV-Vis Analyst application software
  • USB output for the transfer of results

 

Pharmacopoeias 

The CamSpec M550V passes the following pharmacopoeia tests:

  • Potassium Chloride stray light test
  • Toluene in Hexane resolution test
  • Holmium Perchlorate solution wavelength test
  • Potassium Dichromate absorbance test


Technical Specifications

DisplayGraphic LCD (320×240 )dot
Light SourceTungsten-Halogen and Deuterium
MonochromatorDouble beam, grating 1200 lines/mm
DetectorsSilicon Photodiode
Wavelenth Range190-1100nm
Wavelength Accuracy±0.3nm
Wavelength Repeatability≤0.1nm
Wavelength Resolution±0.1nm
Stability±[email protected]
Sample CompartmentVarious Accessories Available
Standard Cell Holder1 Sample; 1 Reference for 10mm cells
SoftwareUV-Vis Analyst, optional
Zero Drift<0.001A per hour after warm up
Bandpass0.5, 1, 2 and 4nm
Stray Light<0.1%@220nm&340nm
Photometric Accuracy±0.5%
Photometric Range0-200%T, -0.3-3.0A
Printer InterfaceParallel for A4 HP and Epson Printers
Computer InterfaceUSB for PC control and USB for data export
Power Requirements100V-240V AC, 50Hz/60Hz
Instrument Dimensions (lxwxh)405x625x280
Instrument Weight24.0kg
Shipping Dimensions (lxwxh)770x580x420mm
Shipping Weight26.7kg

Contact us

If you have any questions or require further information, please do not hesitate to email us at [email protected], call us on +44 (0)113 286 4536 or submit a contact form.